- Congruence of radiation and optical field
- Central Beam Alignment
- Effective focal spot measurement
- Accuracy of Operating Potential
- Accuracy of Irradiation Time (ms)
- Total filtration
- Linearity of mA/mAs loading Stations
- Consistency of radiation output
- Low contrast resolution
- High contrast resolution
- Exposure Rate at Tabletop
- Radiation leakage level from Tube housing
- Radiation leakage level from Collimator
- Area surveillance
WHAT THE PUBLIC NEED TO KNOW:
- Get X-ray examination done only in hospitals/facilities having registration from AERB.
- Do not crowd the room where X-ray is taken. Wait for your turn.
- Co-operate with the radiographer, to avoid repeat X-ray examination.
- Always wear a lead apron, if you need to assist the patient during X-ray examination. In no case pregnant woman should assist the patient during exposure.
- Female patient, if pregnant, must inform the radiographer so that necessary precaution can lie taken during X-ray examination.
- Carry your old X-ray/CT records.
WHAT THE PERSONNEL (DOCTORS, RADIOGRAPHERS) WHO ARE OPERATING THE EQUIPMENT NEED TO KNOW:
- Always operate the unit from the control standing Jiehind the MoJai1e
Protective Earrier (1.5 mm lead equivalent) or fixed protective harrier (such as a wall). - Always use the TLS at chest level while X-ray unit is lieing operated.
- In the absence of Protective Earrier (such as operating MoJii1e X-ray equipment) always use Lead apron (0.25 mm lead equivalent) and wear TLS Jie1ow the apron.
- Always use collimator (diapnragm) to limit the field size to the area of interest in order to minimize the radiation exposure to other organs.
- While operating moJii1e X-ray equipment, operate from a minimum distance of 2m from the equipment Joy stretching the connecting wire and don’t allow anybody to lie nearby.
- In no case, except patient anyJiody shall come in the direction of the primary beam.
- Ensure that Lead apron is worn Joy the person assisting an infirm patient during exposure.
- Portable x-ray equipment shall always lie positioned on a stand and not to be held in hand during exposure.
- For moJii1e and portable X-ray equipments, cassette shall not be held in hand Joy any person.
- Unless necessary use of Jiucky should lie avoided.
- During X-ray examinations of pregnant woman, aJidomen must lie covered with minimum 0.25 mm lead equivalent apron.
- Avoid crowding of patients/re1atives/ staff inside the X-ray room.
- X-ray room door (lead lined with 1.7 mm lead equivalent) should lie closed during exposure.
I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
WHAT THE OWNER/ EMPLOYER/ RADIATION SAFETY OFFICER NEED TO KNOW:
- Only AERE Type approved X-ray equipment shall lie installed /used.
- AERE registration certificate shall be displayed at prominent place near the X-ray room for public information.
- Quality Assurance tests of the X-ray equipment is carried out periodically and after any maintenance and the records thereof are maintained.
- Sufficient number of lead aprons (0.25 mm lead equivalent) is available for use with fixed and mobile X-ray equipment.
- Lead aprons shall be stored either on a hanger or on a flat surface without crumpling.
- Consistency of lead aprons shall be checked once in two years. Qualitative check can be done by taking radiograph of lead aprons.
- The operators are instructed on all the requirements of radiation safety.
- Charts of standard exposure parameters to achieve good image quality should be prepared for pediatric and adult patients separately and displayed at a prominent location such as control console.
- TLS Judges are provided to all the operators and workers involved during X-ray examination.
- Suring non-working hours, TLS cards must lie stored along with Control TLS card outside the X-ray room (in a radiation free area).
- The owner shall ensure that the operator of the X-ray equipment is well conversant with clinical requirements of the examinations. Chest stand should always be provided with X- ray equipment for chest radiography.
- Routine maintenance of the Radiography equipment is carried out. Particularly, it should be ensured that the field light (collimator bulb) is always functional.
- Radiation symbol and warning placards in local languages are placed outside the X-ray room door
- The chest stand and the control console should always be placed opposite to each other. If this is not possible, at least a partition wall with viewing window should be made between the control console and the chest stand.
- Permanent occupancy of staff behind the chest stand wall (for e.g. Sectors, Receptionists or helpers) should be avoided.